คำอธิบาย
Specification
Network Parameters
Port Number 8 × Gigabit PoE ports, and 2 × Gigabit fiber optical ports
Port Type RJ45 port, full duplex, MDI/MDI-X adaptive
Working Mode Standard mode (default) Extend mode
Standard IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab, and IEEE 802.3z
Forwarding Mode Store-and-forward switching
MAC Address Table 8 K
Internal Cache 4.1 Mbits
Switching Capacity 20 Gbps
Packet Forwarding Rate 14.88 Mpps
PoE Power Supply
PoE Standard IEEE 802.3af, IEEE 802.3at
PoE Power Pin End-span: 1/2(-), 3/6(+)
PoE Port Ports 1 to 8
Max. Port Power 30 W
PoE Power Budget 110 W
Software Function
Port Configuration Port rate configuration, flow control, and ports enabling
Device Maintenance Remote upgrade, default parameters recovery, logs viewing, basic network parameters configuration, import and export configuration, time sync
Link Aggregation Static link aggregation supported
Long Range Up to 300 m transmission
PoE Configuration PoE watchdog: Ports 1 to 8 auto detect and restart the cameras that do not respond. PoE enabling: Support
Storm Control Storm control of unknown unicast, multicast and broadcast
Port Mirroring Support
QoS WRR and SP scheduling and port priority
VLAN 4094 VLANs
STP STP and RSTP protocols
Port Isolation Ports in isolation group cannot communicate with each other.
LLDP LLDP protocol supported for port configuration, global configuration and neighbor discovery
Port Rate-Limiting Rate-limiting for ingress and egress ports
SNMP SNMPv1 and SNMPv2c supported for obtaining node information of the system and interfaces
General
Dimension (W × H × D) 217.6 mm × 108.55 mm × 27.8 mm (8.57” × 4.27” × 1.09”)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Gross Weight 1.3 kg (2.87 lb)
Net Weight 1.21 kg (2.67 lb)
Power Consumption In Idle 7 W
Shell Metal material
Operating Temperature -10°C to 55°C (14°F to 131°F)
Operating Humidity 5% to 95% (no condensation)
Power Supply 48 VDC, 2.5 A
Max. Power Consumption 120 W
Relative Humidity 5% to 95% (no condensation)
Approval
EMC FCC (47 CFR Part 15, Subpart B); CE-EMC (EN 55032: 2015, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011 +A1: 2014, EN 55035: 2017); IC (ICES-003: Issue 6); RCM (AS/NZS CISPR 32: 2015)
Safety UL (UL 60950-1); CB (IEC 60950-1:2005, AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition); CE-LVD (EN 60950-1: 2006 + A11: 2009 +A1: 2010+A12: 2011+A2: 2013, EN 62368-1: 2014+A11: 2017)
Chemistry CE-RoHS (2011/65/EU); WEEE (2012/19/EU); Reach (Regulation (EC) No.1907/2006)